MAIN PAGE   NEWS    

 News

HABER

We participated to Fire &

Mavili Elektronik has participated to FIRE & SECURITY PAKISTAN between 19-22 May in Karachi Expo Centre. The International Fir...

 

Maxlogic Continues Certif

Maxlogic Continues Certifying its Quality Our brand Maxlogic, continues to prove its quality… ML series fire alarm control p...

 

2-stage gas detection tec

ML-4218 series gas alarm control panel, which produced by the surface mount technology, have a modern appearance, and a highly eff...

 

MIPS 2010 Exhibition/Mosc

MIPS 2010 Exhibition 16th Moscow International Exhibition «Protection, Security and Fire Safety» 19-22 April, 2010, Expocenter...

 

Security and Safety Tech.

International Forum «Security and Safety Technologies - 2010» «Mavili Elektronik» participated to «Security and Safety Technolog...

 

 Search for product



 

User sign in

   

E-Mail:

Password:

 

Create account | Forget password

 A Milestone Innovation-ML-125XX series

News date: 16.11.2009 08:46:34 


 

Maxlogic series intelligent analogue addressable fire alarm control panels have been designed with an advanced microprocessor technology.

The fire alarm control panels, which have been produced with the surface mount technology, are fully compatible with EN 54-2 and EN 54-4 Standards. The control panels are able to operate with all Mavigard Harezmic series addressable devices.

The fire alarm control panels, offering the feature of creating network structure with Panels and / or Repeater Panels up to 64, can reach up to 130,048 address capacity thanks to the modular structure expandable from 1 loop to 16 loops. Furthermore, 0-loop model fire alarm control panels can be used as Repeater Panels.
The fire alarm control panels with the loop polling feature in such a short time of 7.5 seconds, utilizes Very Intelligent Protocol (VIP) for communication.

Due to the communication protocol, loop polling time is not affected by the number of devices connected to the loop.

“The interrupt” feature, which have an absolute importance on communication protocol, intervene into the system in case of generation of any fire alarm signal.

Upon the intervention of this feature, the fire alarm control panel checks the measured value by the detector couple of times in such a short time of 1.5 seconds.

A similar control mechanism for faulty events prevents time loss for notification of any incoming event.

All polling processes are protected against any possible interference by bit parity checking, which provide the proper data transmission.

Fire alarm control panels, having 1,000 programmable zones, can interact with the BMS (Building Management Systems) via the automation scenarios, which can be created by the feature of 1,000 programmable zone capacities.

The input / output modules (except of the interface modules connected to the loop), which can be directly connected to the fire alarm control panel make possible to include the panel in various automation scenarios with an advanced range of products.

Advanced level fire scenarios for large-scale projects can be created with input / output device event type selection and with the options of enhanced parametric arrangements.

Intelligent analogue addressable detectors, addressable manual call points, loop-powered addressable sounders, interface modules and addressable gas detectors can be programmed to operate in cause-effect scenarios and can be included in fire automation.

Fire alarm control panels utilize real time clock and all the event logs i.e. fire, fault etc. are saved to the event log memory with the capacity of 1,000 events. The fire alarm signal is displayed as prior and the panels have the feature of categorical classification of events and different buttons for fire and other types of events are provided.

4 programmable remote control inputs make the panel available for being controlled from a distant location. Thanks to this feature; it is possible to put the system into the alarm state or into the fault state, disable the sounders and resetting the panel without need to go beside the panel.

All the peripheral devices like the printer module, power supply, loop extension cards etc. are always monitored for any possible faulty event and check of the proper operation of system is made by this way.
Day / Night Mode feature of panels makes possible to change pre-alarm and contamination level thresholds. By this way, a reliable fire alarm system can be installed in places where there exist different environmental conditions between day and night.

Fire alarm control panel offers enhanced computer communication possibilities. RS232 and RS485 ports are used for near access. In such circumstances that distant access is required, the communication can be established by using GPRS and TCP/IP ports.

The Loop Manager Software, which has been specifically developed for the configuration of fire alarm control panel, has the virtual panel application feature. This feature allows accessing all functions without need to go beside the panel.

Monitoring and controlling of a system, in which Maxlogic series intelligent analogue addressable fire alarm control panel is used, can be realized with the Supervisor Software.

The Supervisor Software can run through the fire alarm control panel as well as under Windows Operating System.

Touch screen LCD with the Supervisor Software can be mounted into the control panels and allows dominating the whole system from one central location.

By this way, the entire architectural plan can be displayed on the panels found in security points and much faster detection for any possible fire alarm signals is realized through the project plan.

Supervisor Software can operate with the CCTV system of the site. Besides graphically monitoring the
zone in fire, the live monitoring of the zone can also be realized through the panel.

The conversation between control panels is realized via Telephone Modules in projects where there exists network application and there exist more than 1 control panel.

Furthermore; each panel can be called from one single central point by using Soft Phone application, which can be integrated into the Supervisor Software. The conference conversation between every single panel can also be made.

Except of Telephone Modules, the Firefighter Telephones, which can be installed in different zones of the site, can also be included in the communication network.

Public Announce Modules and Alarm Matrix Modules can intervene in the current announcement system of the site.

Thanks to this feature, the evacuation announcement can be made via the current announcement system of the site through the fire alarm control panel.

Event logs can be printed instantaneously or collectively by the Printer Module, which can be mounted into the fire alarm control panel.

Thanks to the categorical event filtering feature of fire alarm control panels, a specific event type can be accessed much easier by the user.

Advanced controlling and monitoring features of fire alarm control panels shine through thanks to the ease of controlling provided by a great number of control buttons and thanks to the LCD with 240 x 64 adjustable blue backlight, which indicates the fire alarm, fault and other information in detail.

Panel menu, serigraphy and Loop Manager Software have 3 language options as Turkish, English and Russian.

Firmware of fire alarm control panels can be updated on site via Boot Loader Software.

By this way, older versions of fire alarm control panels are always kept up-to-date.

Availability of creating user-defined event types, like considering a fire alarm signal generated from a specific detector as a fire event, fault event or evacuation or like considering a signal coming from an interface module as a faulty event signal.

All outputs of panels have latching / non-latching and interruptible options. These options can be changed easily through the panel in parallel with the requirements of application.

Unauthorized people are not allowed to use the system by the help of key control structure.




Maxlogic_ML-125XX_presentation_file

Show all news   

 All rights reserved 2009 Mavili A.S. (MaviGard and maxlogic registered trademarks of Mavili A.S.)

 Tel: +90216 466 45 05   Fax: +90216 466 45 10